Items |
Technical standards |
|
| Assigned or designated frequency | 415.5 - 417.5MHz, 460.0 - 462.0MHz | |
| Number of channels or channel separation | 25kHz separation | |
| Tolerance of frequency | For over 1 W: ±1.2×10-6 ±(0.7 + A*)×10-6 Note (*) : The "A" is frequency error of reference station when frequency follow-up function is used. For 1W or less: ± 3.0 ×10-6 |
|
| Tolerance of occupied bandwidth | Within 24.3kHz | |
| Tolerance of spurious and unwanted emission intensity | For over 1W : - 60dBc or 2.5µW, or less For 1W or less : 25µW or less |
|
| Antenna power | Designated | Land mobile station: 3W or less |
| Error | +20%, -50% | |
| Tolerance of adjacent channel leakage power | In frequency band of ±R at 25kHz detuning from carrier frequency
(R : 1/4 of transmission rate of modulation signal); For over 1W: - 55 dBc or 32µW, or less For 1W or less : - 45dBc or less |
|
| Leakage power at no carrier transmission | Within occupied bandwidth : - 50dBm or less Out of occupied bandwidth : 4nW or less |
|
| Transmission rate of modulation signal | 32kbps or more | |
| Limit of secondary radiated emissions | 4nW or less | |
| Control device |
(1) Control device for land mobile station (Radio equipment specified
in item 1 - 39 of Article 2 of Certification Ordinance); (2) Land mobile station that can directly communicate with other land
mobile station (Radio equipment specified in item 1 - 40 of Article 2
of Certification Ordinance); |
|
| Notice: Regulations in the Ordinance Regulating Radio Equipment shall have priority over the descriptions in the sheet when any difference is found between them. Further above descriptions do not cover all of the regulations. |