800MHz band Digital MCA (Item 20-2 of Article 2 Paragraph 1 of Certification Ordinance)



Items

Technical standards

Class of emissions ----
Assigned frequency or designated frequency 891 - 893MHz
905 - 915MHz
Number of channels or channel separation 25kHz separation
Tolerance of frequency (×10-6) 3
Tolerance of occupied bandwidth 24.3kHz
Tolerance of spurious or unwanted emission intensity 1W or less 25µW or less
Over 1W -60dBc or 2.5µW or less
Antenna power Designated value 50W or less
(2W or less for land mobile station)
Tolerance +20%, -50%
Tolerance of adjacent channel leakage power 1W or less : -45dBc or less
Over 1W : -55dBc or 32µW or less
in the band of ±R at 25% detuning from carrier frequency (R : 1/4 of transmission rate of modulation signal)
Leakage power at no-carrier transmission In band : -50dBm or less
Out of band : 4nW or less
Transmission rate of modulation signal 32kbps or more
Limit of secondary radiated emissions 4nW or less
Control equipment Confirmation of memory unit
Automatic control of antenna power
Frequency selection
Communication time restriction
Suspension of radio wave transmission

Notice: Regulations in the Ordinance Regulating Radio Equipment shall have priority over the descriptions in the sheet when any difference is found between them. Further above descriptions do not cover all of the regulations.