1.9 GHz band fixed relay station (Item 36 of Article 2 Paragraph 1 of Certification Ordinance)



Items

Technical standards

Class of emissions G1 CDEFXW
G7 DW
Assigned frequency or designated frequency 1893.65 - 1919.45MHz
Number of channels or channel separation 300kHz
Tolerance of frequency (×10-6) 3
Tolerance of occupied bandwidth 288kHz
Tolerance of spurious and unwanted emission intensity 1893.5 - 1919.6MHz 250nW
1893.5MHz or lower
Over 1919.6MHz
2.5µW
Antenna power Designated value 0.16W or less
Tolerance +20%, -50%
Tolerance of adjacent channel leakage power 800nW at 600kHz detuning
250nW at 900kHz detuning
Leakage power at no-carrier transmission 80nW
Transmission rate of modulation signal 384kbps (100 ppm)
Limit of secondary radiated emissions 4nW
Overall operation test ----
Other equipment or function Carrier sensing function
Note ----

Notice: Regulations in the Ordinance Regulating Radio Equipment shall have priority over the descriptions in the sheet when any difference is found between them. Further above descriptions do not cover all of the regulations.

Copyright 2006 TELECOM ENGINEERING CENTER.