| Test items | Technical standards | ||||
|---|---|---|---|---|---|
| Land mobile station | Base station | Relay station | Test station | ||
| Class of emissions | G1 CDEFXW G7 CDEFXW D1 CDEFXW D7 CDEFXW (Control channel: D1D, G1D) |
||||
| Assigned frequency or designated frequency | 1884.65 - 1919.45MHz | ||||
| Number of channels or channel separation | 117 300kHz |
||||
| Tolerance of frequency (×10-6) | 3 | ||||
| Tolerance of occupied bandwidth | Over 1893.5 through 1919.6MHz : 288kHz Over 1884.5 through 1893.5MHz : 884kHz |
||||
| Tolerance of spurious and unawanted emission intensity | In-band | 794nW / MHz | |||
| Out-band | Below 1884.5MHz or over 1919.6MHz: 794nW/MHz 1920MHz or higher to 1980MHz or lower: 251nW/MHz 2110MHz or higher to 2170MHz or lower: 251nW/MHz (Detuning: 2.25MHz) |
||||
| Antenna power | Designated value | 0.01W | To base station:0.01W To mobile station: 0.02W (1893.65 - 1905.95: 0.01W) |
1884.65 - 1893.35MHz : 0.5W 1893.65 - 1905.95MHz : 0.02W 1906.25 - 1908.05MHz: 0.5W (2W*) 1908.35 - 1915.55MHz : 0.5W 1915.85 - 1918.25MHz : 0.5W (2W*) 1918.55 - 1919.45MHz : 0.5W |
|
| Tolerance | +20%, -50% | ||||
| Tolerance of adjacent channel leakage power | For occupied bandwidth of 288 kHz or less:800 nW (600 kHz ±96
kHz), 250 nW (900 kHz ±96 kHz) For occupied bandwidth of over 288 kHz:800 nW (900 kHz ±96 kHz), 250 nW (1200 kHz ±96 kHz) |
||||
| Leakage power at no-carrier transmission | 80nW or less | ||||
| Tolerance of modulation signal transmission rate (×10-6) | ±100 | ||||
| Limit of secondary radiated emissions | 4nW | ||||
| Other equipment or function | Land mobile station (1) Carrier sensing (2) Identification device (3) Interference prevention function (4) Communication between slave units (5) Cessation of radio waves Base station,Relay station,Test station (1) Carrier sensing (2) Identification device (5) Cessation of radio waves |
||||
| Overrall operation test | Automatic frequency selection | ---- | ---- | ---- | |
| Notice: Regulations in the Ordinance Regulating Radio Equipment shall have priority over the descriptions in the sheet when any difference is found between them. Further above descriptions do not cover all of the regulations. |